AF2ZP0CE - ACE2 350/450 - User Manual Page - 49/83
Speed reduction when the cutback input is active.
18) FREQUENCY CREEP
Minimum speed when the forward or reverse switch is closed, but the
accelerator is on a minimum position.
19) MAXIMUM CURRENT
This parameter changes the maximum current of the inverter.
20) BRK SMOOTH
It gives a parabolic form to the deceleration ramp.
21) STOP BRK SMOOTH
Hz. It sets the level of frequency where the smooth effect of the deceleration
parabolic form ends.
22) AUXILIARY TIME
Time units value (seconds). For the encoder version, it determines the time
duration the truck is hold on the ramp if the STOP ON RAMP option is ON.
The following table shows the minimum / maximum programmable value for
each parameter. In the table is also present the parameters resolution.
PARAMETER UNIT MIN VALUE MAX VALUE RESOLUTION
ACCELERATION 0 (*) Sec. 0,3 10 0,1
INV. ACCEL 0 (*) Sec. 0,3 10 0,1
ACCELERATION 1 (*) Sec. 0,3 10 0,1
ACCELERATION 2 (*) Sec. 0,3 10 0,1
ACCELERATION 3 (*) Sec. 0,3 10 0,1
ACC PROF. FREQ 1 Hz 0 200 1
ACC PROF. FREQ 2 Hz 0 200 1
ACC PROF. FREQ 3 Hz 0 200 1
RELEASE BRAKING (**) Sec. 0,3 10 0,1
INVERS BRAKING (**) Sec. 0,3 10 0,1
DECELERATION BRAKING (**) Sec. 0,3 10 0,1
PEDAL BRAKING (**) Sec. 0,3 10 0,1
SPEED LIMIT BRAKING (**) Sec. 0,3 10 0,1
MAX SPEED FW Hz 5 200 1
MAX SPEED BW Hz 5 200 1
CUTBACK SPEED 1 %Max Sp 10 100 1
FREQUENCY CREEP Hz 0,6 4 0,1
MAXIMUM CURRENT % IMAX 0 100 1
BRK SMOOTH Num 1 5 0,1
STOP BRK SMOOTH Hz. 3 20 1
AUXILIARY TIME Sec. 0 10 0,1
Comentarios a estos manuales