Zapi AC-2 Manual de usuario Pagina 54

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 83
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 53
Page - 54/83 AF2ZP0CE - ACE2 350/450 - User Manual
8.6 Programming console functions
- Functional configuration (see 8.1, 8.2, 8.3, 8.4).
- Parameter programming (see 8.5.1, 8.5.2).
- Tester: the user can verify the state of the following parameters:
TRACTION PUMP
battery voltage (V) battery voltage (V)
motor voltage (%) motor voltage (%)
voltage booster (%) voltage booster (%)
frequency (Hz) frequency (Hz)
encoder (Hz) encoder (Hz)
slip value (Hz) slip value (Hz)
current rms (A) current rms (A)
motor power (W) motor power (W)
battery charge (%) battery charge (%)
temperature (°C) temperature (°C)
motor temperat. (°C) motor temperature (°C)
accelerator (V) handle/seat switch (ON/OFF)
handle/seat switch (ON/OFF) lifting control (V)
forward switch (ON/OFF) lifting enable (ON/OFF)
backward switch (ON/OFF) 1
st
speed switch (ON/OFF)
cutback switch (ON/OFF) 2
nd
speed switch (ON/OFF)
hand brake (ON/OFF) 3
rd
speed switch (ON/OFF)
Brakepedal pot. (%) hydro speed req. (ON/OFF)
2
ND
hourmeters 2
nd
hourmeters
- Save function (for storing data).
- Restore function (for loading parameters on another inverter).
- Display of the last 5 alarms including hour-meter value and temperature at
the moment of the alarm.
- Accelerator range programming: records the minimum and maximum useful
accelerator stroke values for both direction of running.
- See the console manual for a detailed description of function and
parameters.