10.5 Description of the battery charge detection setting
The Battery Charge detection uses two setting that specify the Full Charge
Voltage Level (100%) and the Discharge Voltage Level (10%). These two
settings are the Bat.Max.Adj and the Bat.Min.Adj. It is possible to adapt the
Battery Charge Detection to your specific battery, by changing the above two
settings (e.g. if the Battery Discharged Detection occurs when the battery is not
totally discharged, it is necessary to reduce the Bat.Min.Adj setting as indicated
in the figure below).
48V NOMINAL BATTERY VOLTAGE
24V NOMINAL BATTERY VOLTAGE