4 INSTALLATION HINTS
In the description of these installation suggestions you will find some boxes of
different colours, they mean:
4 These are information useful for anyone is working on the installation, or a
deeper examination of the content
U These are Warning boxes, they describe:
- operations that can lead to a failure of the electronic device or can be
dangerous or harmful for the operator;
- items which are important to guarantee system performance and safety
4.1 Material overview
Before to start it is necessary to have the required material for a correct
installation. Otherwise a wrong choice of cables or other parts could lead to
failures/ misbehaviour/ bad performances.
4.1.1 Connection cables
For the auxiliary circuits, use cables of 0.5 mm² section.
For power connections to the motor and to the battery, use cables having section
of at least 50 mm².
For the optimum inverter performance, the cables to the battery should be run
side by side and be as short as possible.
4.1.2 Contactors
The main contactor must be installed. Depending on the setting of a parameter in
the controller (PWM ON MAIN CONT; see chapter 8.4.1, 8.4.2):
- the output which drives the main contactor coil is on/off (the coil is driven with
the full battery voltage).
- the output which drives the main contactor coil is modulated with a PWM at
high frequency (1 kHz). After an initial delay of about 1 sec in which the coil is
driven with the full battery voltage, the PWM reduces the voltage down to
62%.This feature is useful to decrease the power dissipation of the contactor
coil.
4.1.3 Fuses
- Use a 10 A Fuse for protection of the auxiliary circuits.
- For protection of the power unit, refer to diagrams. The Fuse value shown is
the maximum allowable. For special applications or requirements these
values can be reduced.
- For Safety reasons, we recommend the use of protected fuses in order to
prevent the spread of fused particles should the fuse blow.