3 SPECIFICATION FOR THE INPUT DEVICES
FILLING UP THE INSTALLATION KIT
The AC-2 FLASH inverter needs some external parts in order to work. The
following devices complete the kit for the AC-2 FLASH installation.
3.1 Microswitches
- The microswitches must have a contact resistance lower than 0.1 and a
leakage current lower than 100 µA.
- When full load connected, the voltage drop between the key switch contacts
must be lower than 0.1 V.
- The microswitches send a voltage signal to the microprocessor when a
function request (for ex.: running request) is made.
3.2 Accelerator unit
The accelerator unit can consist of a potentiometer or an Hall effect device.
It should be in a 3-wire configuration. The potentiometer is supplied through
CNE#2.
Potentiometer output signal must be input to CPOT (CNE#1) signal range is from
0 to 10 V.
The negative supply of the potentiometer has to be taken from CNE#3.
Potentiometer value should be in the 0.5 – 10 k range; generally, the load
should be in the 1.5 mA to 30 mA range. Faults can occur if it is outside this
range.
The standard connection for the potentiometer is the one in the Left side of next
figure (potentiometer on one end at rest) in combination with a couple of Travel
demand switches. On request it is also possible the handling in the Right side of
next figure (potentiometer in the middle at rest) still in combination with a couple
of Travel demand switches.
The Procedure for automatic potentiometer signal acquisition is carried out using
the Console. This enables adjustment of the minimum and maximum useful
signal level (PROGRAM VACC function), in either direction. This function is
unique when it is necessary to compensate for asymmetry with the mechanical
elements associated with the potentiometer, especially relating to the minimum
level.
The sequence of procedure is described in the programming console manual.