Zapi AC-2 Manual de usuario Pagina 41

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 40
ADEZP0DC - AC-2 FLASH INVERTER - User Manual Page - 41/72
6) ADJUSTMENT #04
This parameter determines the motor temperature level at which the “Motor
temperature” alarm is signalled. The range is from 70 °C to 160 °C with 10 °C
steps. This parameter must be adjusted only if the “Set temperature” (menu
“Set option”) parameter is programmed “Analog”.
7) ADJUSTMENT #03
This parameter isn’t used.
8) ADJUSTMENT #02
It adjusts the lower level of the battery discharge table.
9) ADJUSTMENT #01
It adjusts the upper level of the battery discharge table.
10) LOAD HM FROM MDI
For an explanation of this point see the MDI instrument handbook.
11) PWM ON MAIN CONT
- OFF: the inverter applies the battery voltage to the loads on the main
contactor coil.
- ON: the PWM reduces the voltage at the loads on the main contactor
coil down to 62% of the battery voltage.
12) PWM ON AUX OUT.
- OFF: the inverter applies the battery voltage to the loads on the auxiliary
output.
- ON: the PWM reduces the voltage at the loads on the auxiliary output
down to 62% of the battery voltage.
Vista de pagina 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 71 72

Comentarios a estos manuales

Sin comentarios