AESZP0BA – AC1 SSL SENSORED - FREE VERSION - User Manual Page - 35/73
2) SET INPUT #1
This setting handles the analog input CNA#13. It can be used one of three:
- Level 0: CNA#13 is managed as input for an analog motor thermal
sensor KTY84-130.
- Level 1: CNA#13 is managed as a digital cutback speed input
(SR#1).
- Level 2: CNA#13 is managed as a digital handbrake input.
When Level 1 or 2, this input must be connected to a -Batt voltage in order
the selected function is not active; it must be opened to turn the selected
function active.
3) SET INPUT #2
(Standard Version only). This option handles the digital input CNA#14. It can
be used one of two:
- PRESENT: CNA#14 is managed as a cutback speed input (SR#2)
- OPTION #1: CNA#14 is managed as an inching forward input
The input CNA#14 can only be used as Aux Lifting request when the MDI-
PRC is PRESENT.
This input must be connected to a Key voltage.
The SR#2 becomes active when CNA#14 is opened.
The inching forward becomes active when the CNA#14 is closed to a key
voltage.
4) SET INPUT #3
(Standard Version only). This option handles the digital input CNA#15. It can
be used one of two:
- - PRESENT: CNA#15 is managed as a cutback speed input (SR#3)
- - OPTION #1: CNA#15 is managed as an inching backward input
This input must be connected to a Key voltage.
The SR#3 becomes active when CNA#15 is opened.
The inching forward becomes active when the CNA#15 is closed to a key
voltage.
5) SET INPUT #4
This option handles the digital input CNB#7. It can be used one of three:
- BELLY: CNB#7 is managed as a Belly Switch input.
- BRAKE: CNB#7 is managed as service brake input. This
information can be used also to recognize when the
operator is driving with a pressed pedal braking.
- EX.HYDRO: CNB#7 is managed as Exclusive Hydro.
This input must be connected to a Key voltage.
The Belly switch active level is specified on the QUICK INV LOGIC below.
The service brake or the exclusive hydro becomes active when CNB#7 is
opened.
6) HOUR COUNTER
This option specifies the hour counter mode. It can be set one of two:
- RUNNING: The counter registers travel time only
- KEY ON: The counter registers when the "key" switch is closed