Page - 68/73 AESZP0BA – AC1 SSL SENSORED - FREE VERSION - User Manual
than 400msec. The goal of this diagnosis is to detect a failure of
the A/D converter or a problem in the code flow that omits the
refreshing of the analog signal conversion.
- Remedy: If the problem occurs permanently it is necessary to substituite
the controller.
14.1.7 Seven Blinks Alarms
1) HIGH TEMPERATURE
MDI-PRC Code = 61
- Cause: This alarm occurs when the temperature of the base plate is
higher than 90° at 24V or 78° at 48V. Then the maximum
current decreases proportionally with the temperature
increases from 90°(78°) up to 110°(103°). At 103° the Current is
limited to 0 Amps.
- Remedy: Improve the air cooling of the controller.
2) MOTOR TEMPERAT
MDI-PRC Code = 65
- Cause: This is just a warning with no effect on the truck performance. It
occurs when the temperature of the motor winding overtakes
the MOTOR OVERTEMP setting.
- Remedy: Check the thermal sensor inside the motor (use the MOTOR
TEMPERATURE reading in the TESTER menu). If the sensor is
OK, improve the air cooling of the motor.
3) THERMIC SENS KO
MDI-PRC Code = 73
- Cause: When the output of the thermal sensor on the base plate is
higher than 4.95V or lower than 0.1V , the sensor is assumed
failed and this alarm occurs.
- Remedy: It is necessary to substituite the controller.
14.1.8 Eigth Blinks Alarms
1) CAN BUS KO
MDI-PRC Code = 67
- Cause: It occurs if the controller does not receive any message from
the CAN Bus line.
- Remedy: First of all, check the wiring. If it is OK , try to disconnect one to
one the module connected to the CAN Bus and check if this
alarm disappears. When you are quite sure the problem is in
the present module, it is necessary to substituite the controller.
14.1.9 No Blink Alarms
1) STOP TOP
MDI-PRC Code = Null
- Cause: This is just a warning to inform the Passive Emergency Cell
(see 5.1) operates. The Passive Emergency Cell operates
when the controller takes longer than 800msec, after the tiller
was released, to reduce the frequency in the motor, close to
zero. The Passive Emergency Cell siwtches off the Top Side
Power Mosfets (this is the reason for the name) of the three
phase bridge.
- Remedy: The controller exits automatically this warning when the
operator turns the truck moving.