Page - 44/73 AESZP0BA – AC1 SSL SENSORED - FREE VERSION - User Manual
12.4.3 Main menu “PARAMETER CHANGE” functions list
To enter the MAIN MENU’ it is just necessary to push the ENTER button from the
home display in the hand set.
1) Opening Zapi Menu
AC1 ZP 1.00
24V 250A 00000
2) Press ENTER to go into the General Menu
' % '
' ' '
3) The Display will show: PARAMETER CHANGE
MAIN MENU
PARAMETER CHANGE
4) Press ENTER to go into the Parameter
Change facility
' % '
' ' '
5) The Display will show the first parameter
ACC DELAY
LEVEL = 5
6) Press either ROLL UP and ROLL DOWN to
display the next parameter
% ' '
% ' '
7) The names of the Parameters appear on the
Display
RELEASE BRAKING
LEVEL = 5
8) When desired Parameter appear, it’s possible
to change the Level by pressing either SET UP
or SET DOWN buttons.
' ' %
' ' %
9) The Display will show the new level.
RELEASE BRAKING
LEVEL = 2
10) When you are satisfied with the result of the
changes you have made, press OUT.
' ' '
' % '
11) The Display asks: “ARE YOU SURE?”
ARE YOU SURE?
YES=ENTER
NO=OUT
12) Press ENTER to accept the changes, or press
OUT to discard them.
' ' '
' % '
13) The Display will show
MAIN MENU
PARAMETER CHANGE
Figure 12–6
1) ACCELER. DELAY
Level 0 to 9. It determines the acceleration ramp. At Level 9 the truck takes
long time to accelerate.
2) RELEASE BRAKING
Level 0 to 9. It controls the deceleration ramp when the travel request is
released. At Level 9 the truck brakes abrutly.