13.4 Shortform table of the aux output #1 setting
The AUX OUTPUT #1 setting specifies the handling of the CNA#3 output and the
STOP ON RAMP service (when the encoder is used). This handling is
summarized in the table below.
AUX
OUTPUT
STOP ON
RAMP
A3 OUTPUT BEHAVIOUR ON A SLOPE
BRAKE ON -Drives the coil
of a
electromagnetic
brake.
"The truck is electrically hold on a slope; when
the time set by ""auxiliary time"" parameter is
elapsed the brake is applied and the 3-phase
bridge is released. Do not use this
combination if the negative brake is not
installed."
BRAKE OFF -Drives the coil
of a
electromagnetic
brake.
"The truck is not electrically hold on a slope,
but comes down very slowly; when the time
set by ""auxiliary time"" parameter is elapsed,
the brake is applied and the 3-phase bridge is
opened. Do not use this combination if the
negative brake is not installed."
HYDRO
CONT.
ON -Drives the coil
of a hydraulic
steering
contactor.
"The truck is electrically hold on a slope; when
the time set by ""auxiliary time"" parameter is
elapsed, the truck comes down very slowly, till
the flat is reached. "
HYDRO
CONT.
OFF -Drives the coil
of a hydraulic
steering
contactor.
The truck is not electrically hold on a slope,
but comes down very slowly till the flat is
reached.
EXCL.
HYDRO
ON -Drives the coil
of a hydraulic
steering
contactor.
"The truck is electrically hold on a slope; when
the time set by ""auxiliary time"" parameter is
elapsed, the truck comes down very slowly, till
the flat is reached. "
EXCL.
HYDRO
OFF -Drives the coil
of a hydraulic
steering
contactor.
The truck is not electrically hold on a slope,
but comes down very slowly till the flat is
reached.