AESZP0BA – AC1 SSL SENSORED - FREE VERSION - User Manual Page - 37/73
- Command input for lifting/lowering proportional valves in MDI-PRC
version.
To turn from the first to the second function is just enough to set PEDAL
BRAKING to NONE.
This option handles the analog input CNA#18 when used as pedal braking
input:
- ANALOG: With this setting is possible to modulate the strenght of
the braking when the accelerator is released. The
strenght of the braking is proportional to the brake pedal
potentiometer connected to this input.
When the pedal potentiometer voltage is equal less than
the SET POT BRK MIN (see 12.4.2.1) the minimum
release braking strength is applied (following the
RELEASE BRAKING setting).
When the pedal potentiometer voltage is equal higher
than the SET POT BRK MAX (see 12.4.2.2) the maximum
release braking strength is applied (following the PEDAL
BRAKING setting).
In the intermediate position, the electrical braking strength
is a linear function between the minimum (RELEASE
BRAKING) and maximum (PEDAL BRAKING) intensity.
When there is also a switch connected to the pedal
braking (i.e. SET INPUT #4 to level BRAKE), it must be
closed, otherwise the release braking is stuck to the
minimum strength disregarding the pedal potentiometer
position.
- DIGITAL: No pedal potentiometer is expected. Only when both the
SET INPUT #4 is Level BRAKE and the brake switch
connected to CNB#7 is closed, the release electrical
braking follows the PEDAL BRAKING setting (maximum
strength); in all of the other conditions the release
electrical braking follows the RELEASE BRAKING setting
(minimum strenght).
- NONE: The analog input CNA#18 is not used for the release
braking modulation.
12) QUICK INVERSION
This option specifies the quick inversion mode when the SET INPUT #4 is set
BELLY. It can be set one of three:
- NONE: The quick inversion function is not managed (no effect
when CNB#7 switches over).
- TIMED: The quick inversion function is timed.
- BELLY: The quick inversion function is managed but not timed.
13) AUX VOLTAGE #1
This option specifies the percentage of the key voltage to be applied to the
loads on CNA#1 (main contactor coil) and CNA#3 (electromechanical brake).
The voltage modulation is got with a PWM at 1KHZ frequency. After an initial
delay of about 1 sec in which the entire key voltage is applied to the loads,
the PWM reduces the voltage at the loads down to the specified percentage.